BSJJY - BIG 90 AEROSOL, 0201

  • MSDS: BSJJY
  • Manufacturer: SELIG CHEMICAL IND
  • Product Name: BIG 90 AEROSOL, 0201
  • National Stock Number: 7930-00N041197
Product Identification

Product ID:BIG 90 AEROSOL, 0201
MSDS Date:09/05/1991
FSC:7930
NIIN:00N041197
MSDS Number: BSJJY

Responsible Party
SELIG CHEMICAL IND
840 SELIG DR SW
ATLANTA, GA 30378
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 404-691-9220

Cage: 86938

Contractor
SELIG CHEMICAL INDUS, DIV OF NATIONAL SERVICE INDUS
ATLANTA, GA 30378 US

Telephone: 404-691-9220

Cage: 86938

Ingredients

LIGROINE; (MINERAL SPIRITS)

CAS: 8032-32-4

RTECS: OI6180000

Fraction By Weight: 80-95%

OSHA PEL 300 PPM;400 STEL

ACGIH TLV: 300 PPM


ETHANOL, 2-BUTOXY-; (2-BUTOXYETHANOL)

CAS: 111-76-2

RTECS: KJ8575000

Fraction By Weight: 1-3%

OSHA PEL 25 PPM, S

ACGIH TLV: 25 PPM, S

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: CAN CAUSE IRRITATION UPON
PROLONGED CONTACT. EYES: CAN BE IRRITATING UPON CONTACT.
INHALATION: CAN CAUSE DIZZINESS, NAUSEA AND HEADACHE UPON PROLONGED
EXPOSURE. INGESTION: CAN CAUSE NAUSEA AND V OMITING. ANIMAL STUDIES
CLEARLY DEMONSTRATED DOSE-RELATED ADVERSE EFFECTS ON CNS,
HEMATOPOIETIC TISS, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HEALTH HAZARDS: BLOOD, KIDNEYS AND LIVER,
ASSOCIATED WITH ADMINSTRATION OF 2-BUTOXYETHANOL. (EXTRACTED FROM
DHHS (NIOSH) PUBLICATION NO. 90-118) .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN: WASH WITH SOAP AND WATER. EYE: FLUSH IMMEDIATELY WITH
PLENTY OF WATER FOR AT LEAST 15 MINUTES. CONSULT PHYSICIAN.
INHALATION: REMOVE TO FRESH AIR. GIVE OXYGEN, IF NEEDED. SEE
DOCTOR. INGESTION: CALL MD IMMEDIATELY .

Fire Fighting

Flash Point:SPRAY FLAMMABLE
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:LRG SPILLS ARE UNLIKELY DUE TO AEROSOL
PACKAGING. IF SPILLED, ABSORB WITH AN ABSORB MATL (I.E. SELIG'S AP
ABSORB), PICK UP & DEPOSIT IN SEALABLE CONTAINER FOR DISP AS HAZ
WASTE. THORO CLEAN SPILL AREA WITH DETERGENT SOLN. RINSE THORO
W/CLEAN WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:CONTAINER MAY BURST IF HEATED ABOVE
120F.
Other Precautions:AVOID PROLONGED EXPOSURE TO VAPORS. AVOID CONTACT
WITH SKIN AND EYES. HARMFUL IF SWALLOWED. KEEP OUT OF REACH OF
CHILDREN.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED CHEMICAL CARTRIDGE
RESPIRATOR IF IN UNVENTILATED AREA.
Ventilation:MECHANICAL VENTILATION.
Protective Gloves:RUBBER OR NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FLASH POINT METHOD: CSMA FLAME EXT. TEST. WASTE DISPOSAL METHOD: PROPER
DISPOSAL METHOD IN YOUR AREA. FEDERAL HAZARDOUS WASTE NUMBER: D001.

Chemical Properties

Spec Gravity:0.77
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR, LIGHT AMBER LIQUID WITH SOLVENT ODOR.
Percent Volatiles by Volume:80

Stability

Stability Indicator/Materials to Avoid:YES
WATER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION MAY YIELD CARBON
MONOXIDE.

Disposal

Waste Disposal Methods:PROD IS CONSUMED IN USE.WHEN DISP OF SPENT
CNTNRS,DO NOT CRUSH, PUNCTURE/INCIN. SML HAZ WASTE GENERATORS
SHOULD CONSULT CFR TITLE 40, PART 261.5 FOR POSS EXEMPTIONS. SINCE
REGS VARY CONCERNING DISP OF CHEMS, CONSULT LOC,ST & FED AGENCIES
FOR (SUPDAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.